Process air cooler/chiller/chiller, air-cooled, Type: TAEevo Tech 1002 P3 MTA S.p.A. TAEevo Tech 1002 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 950 ltr., built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 200 [682428 Btu (IT)/h] Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 34.2 Available pump pressure (bar) 3.09 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 99 Max. Current (A) 167 Starting Current Circuit (A) 371 Protection class: IP54 Dimensions: Length (mm) 4655, Width (mm) 1250, Height (mm) 2155 Weight (kg) 2998 Victaulic DN 100 Connector Serial No.: 2200404931 ...
Process air cooler/chiller/chiller, air-cooled, Type: TAEevo Tech 1002 P3 MTA S.p.A. TAEevo Tech 1002 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 950 ltr., built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 200 [682428 Btu (IT)/h] Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 34.2 Available pump pressure (bar) 3.09 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 99 Max. Current (A) 167 Starting Current Circuit (A) 371 Protection class: IP54 Dimensions: Length (mm) 4655, Width (mm) 1250, Height (mm) 2155 Weight (kg) 2998 Victaulic DN 100 Connector Serial No.: 2200404931 ...
Process chiller / chiller air-cooled for duct connection Type: TAEevo Tech 101 P5-RAD Refrigeration Machines, MTA S.p.A. TAEevo Tech 101 P5-RAD are air-cooled compact water chillers suitable for outdoor installation (-20°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 255 ltr. And built-in P5 high-pressure pump radial blower for duct connection (air volume flow 14200 m3/h and external delivery pressure of 134 Pa) Extras: - Speed control of the fans - Open storage tank - Bypass with socket slide Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 25.7 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 4.34 Available pump pressure (bar) 4.96 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 20 Max. ...
Process chiller / chiller air-cooled for duct connection Type: TAEevo Tech 101 P5-RAD Refrigeration Machines, MTA S.p.A. TAEevo Tech 101 P5-RAD are air-cooled compact water chillers suitable for outdoor installation (-20°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 255 ltr. And built-in P5 high-pressure pump radial blower for duct connection (air volume flow 14200 m3/h and external delivery pressure of 134 Pa) Extras: - Speed control of the fans - Open storage tank - Bypass with socket slide Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 25.7 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 4.34 Available pump pressure (bar) 4.96 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 20 Max. ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 101 P3-MAG MTA S.p.A. TAEevo Tech 101 P3-MAG are air-cooled compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 255 ltr. And built-in P3 pump. Extras: - MAG kit expansion vessel 6 litres, safety valve 3 bar - Ball valves on the water connection - Socket slide at the outlet Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 27.5 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 4.68 Available pump pressure (bar) 2.54 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 14 Max. current (A) 25 Starting Current Circuit (A) 123 Protection class: IP54 Dimensions: Length (mm) 1862, Widt ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 101 P3-MAG MTA S.p.A. TAEevo Tech 101 P3-MAG are air-cooled compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 255 ltr. And built-in P3 pump. Extras: - MAG kit expansion vessel 6 litres, safety valve 3 bar - Ball valves on the water connection - Socket slide at the outlet Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 27.5 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 4.68 Available pump pressure (bar) 2.54 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 14 Max. current (A) 25 Starting Current Circuit (A) 123 Protection class: IP54 Dimensions: Length (mm) 1862, Widt ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 351 P5-offAD bypass MTA S.p.A. chiller, chiller; Radiator TAEevo Tech 351 P5-offAD Bypass are air-cooled compact water chillers suitable for outdoor installation down to -5°C. Including crank pan heater, electronic expansion valves, phase monitoring, buffer tank 350 liters and built-in P5 high-pressure pump. Extras: - Open filling system/ tank attached - Bypass with manual valve between water inlet and outlet Cooling capacity kW 66 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 11.2 Available pump pressure (bar) 4.68 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 39 Max. Current (A) 68 Starting Current Circuit (A) 213 Protection class: IP54 Dimensions: Length (mm) 2250, Width (mm) 866, Height ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 351 P5-offAD bypass MTA S.p.A. chiller, chiller; Radiator TAEevo Tech 351 P5-offAD Bypass are air-cooled compact water chillers suitable for outdoor installation down to -5°C. Including crank pan heater, electronic expansion valves, phase monitoring, buffer tank 350 liters and built-in P5 high-pressure pump. Extras: - Open filling system/ tank attached - Bypass with manual valve between water inlet and outlet Cooling capacity kW 66 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 11.2 Available pump pressure (bar) 4.68 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 39 Max. Current (A) 68 Starting Current Circuit (A) 213 Protection class: IP54 Dimensions: Length (mm) 2250, Width (mm) 866, Height ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 802 P3-20 MTA S.p.A. TAEevo Tech 802 P3-20 are air-cooled compact water chillers suitable for outdoor installation (from -20°C to +46°C). Including crank pan heating, phase monitoring, electronic injectors, buffer tank 678 ltr., built-in P3 circulation pump on the intake side and winter control (condenser pressure control -20°C). Cooling capacity kW 159 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 27.1 Available pump pressure (bar) 3.13 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 79.48 Max. Current (A) 142.2 Starting Current Circuit (A) 286.2 Protection class: IP54 Dimensions: Length (mm) 3535, Width (mm) 1250, Height (mm) 2151, Weight (kg) 2192 Connection Rp 3 Serial No.: 2200374246 Yea ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 802 P3-20 MTA S.p.A. TAEevo Tech 802 P3-20 are air-cooled compact water chillers suitable for outdoor installation (from -20°C to +46°C). Including crank pan heating, phase monitoring, electronic injectors, buffer tank 678 ltr., built-in P3 circulation pump on the intake side and winter control (condenser pressure control -20°C). Cooling capacity kW 159 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 27.1 Available pump pressure (bar) 3.13 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 79.48 Max. Current (A) 142.2 Starting Current Circuit (A) 286.2 Protection class: IP54 Dimensions: Length (mm) 3535, Width (mm) 1250, Height (mm) 2151, Weight (kg) 2192 Connection Rp 3 Serial No.: 2200374246 Yea ...
Process Air Cooler/Chiller/Chiller Air Cooled, Type: TAEevo Tech 301 P3-20 MTA S.p.A. TAEevo Tech 301P3-20 are air-cooled compact water chillers suitable for outdoor installation from -20°C to +46°C. Includes crank pan heater, electronic expansion valves, phase monitoring, buffer tank 350 ltr., built-in P3 circulation pump and condenser pressure control (winter package). Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 59.3 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow rate (m³/h) 10.1 Available pump pressure (bar) 3.14 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 31 Max. Current (A) 54 Starting Current Circuit (A) 168 Protection class: IP54 Dimensions: Length (mm) 2250, Width (mm) 866, Height (mm) 2054, Weight (k ...
Process Air Cooler/Chiller/Chiller Air Cooled, Type: TAEevo Tech 301 P3-20 MTA S.p.A. TAEevo Tech 301P3-20 are air-cooled compact water chillers suitable for outdoor installation from -20°C to +46°C. Includes crank pan heater, electronic expansion valves, phase monitoring, buffer tank 350 ltr., built-in P3 circulation pump and condenser pressure control (winter package). Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 59.3 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow rate (m³/h) 10.1 Available pump pressure (bar) 3.14 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 31 Max. Current (A) 54 Starting Current Circuit (A) 168 Protection class: IP54 Dimensions: Length (mm) 2250, Width (mm) 866, Height (mm) 2054, Weight ( ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 251 P5 MTA S.p.A. TAEevo Tech 251P5 are air-cooled compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank tray heating, phase monitoring, buffer tank 350 ltr. and built-in P5 high-pressure circulation pump. Cooling capacity kW 48.7 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 8.26 Available pump pressure (bar) 4.93 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 29 Max. current (A) 50 Starting Current Circuit (A) 149 Protection class: IP54 Dimensions: Length (mm) 2250, Width (mm) 866, Height (mm) 2054, Weight (kg) 1034 Connection Rp 2 Serial No.: 2200384598 Year of construction 2022 Condition: Optical 2, Technically ok Used Price: on request in Euro ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 251 P5 MTA S.p.A. TAEevo Tech 251P5 are air-cooled compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank tray heating, phase monitoring, buffer tank 350 ltr. and built-in P5 high-pressure circulation pump. Cooling capacity kW 48.7 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 8.26 Available pump pressure (bar) 4.93 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 29 Max. current (A) 50 Starting Current Circuit (A) 149 Protection class: IP54 Dimensions: Length (mm) 2250, Width (mm) 866, Height (mm) 2054, Weight (kg) 1034 Connection Rp 2 Serial No.: 2200384598 Year of construction 2022 Condition: Optical 2, Technically ok Used Price: on request in Euro ...
Process air cooler/ chiller/ chiller, air-cooled, Type: TAEevo Tech 121 P5 MTA S.p.A. TAEevo Tech 121 P5 are air-cooled compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 255 ltr. and built-in P5 high-pressure circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 35 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 5.92 Available pump pressure (bar) 4.74 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 20 Max. Current (A) 35 Starting Current Circuit (A) 167 Protection class: IP54 Dimensions: Length (mm) 1862, Width (mm) 761, Height (mm) 1437, Weight (kg) 661 Connection Rp 1 1/2 Serial No.: 2200387884 Year of construc ...
Process air cooler/ chiller/ chiller, air-cooled, Type: TAEevo Tech 121 P5 MTA S.p.A. TAEevo Tech 121 P5 are air-cooled compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 255 ltr. and built-in P5 high-pressure circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 35 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 5.92 Available pump pressure (bar) 4.74 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 20 Max. Current (A) 35 Starting Current Circuit (A) 167 Protection class: IP54 Dimensions: Length (mm) 1862, Width (mm) 761, Height (mm) 1437, Weight (kg) 661 Connection Rp 1 1/2 Serial No.: 2200387884 Year of construc ...
Process air cooler/ chiller/ chiller, air-cooled, Type: TAEevo Tech 031 P3 MTA S.p.A. TAEevo Tech 031 P3 are air-cooled compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 115 ltr., built-in P3 pump on suction side (for open systems). Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 9.1 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 1.53 Available pump pressure (bar) 2.93 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 5.9 Max. Current (A) 10 Starting Current Circuit (A) 46 Protection class: IP54 Dimensions: Length (mm) 1315, Width (mm) 660, Height (mm) 1373, Weight (kg) 326 Connection Rp 1 Serial No.: 2200385701 Year of c ...
Process air cooler/ chiller/ chiller, air-cooled, Type: TAEevo Tech 031 P3 MTA S.p.A. TAEevo Tech 031 P3 are air-cooled compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 115 ltr., built-in P3 pump on suction side (for open systems). Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 9.1 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 1.53 Available pump pressure (bar) 2.93 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 5.9 Max. Current (A) 10 Starting Current Circuit (A) 46 Protection class: IP54 Dimensions: Length (mm) 1315, Width (mm) 660, Height (mm) 1373, Weight (kg) 326 Connection Rp 1 Serial No.: 2200385701 Year of ...
Process refrigeration machine / chiller air-cooled, Type: TAEevo Tech 402 P3-20 MTA S.p.A. TAEevo Tech 402 P3-20 are air-cooled compact water chillers suitable for outdoor installation (-20°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 500 ltr., built-in P3 Circulation pump and condensation pressure control. Cooling capacity kW 89.4 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 15.2 Available pump pressure (bar) 3.45 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 48 Max. Current (A) 81 Starting Current Circuit (A) 176 Protection class: IP54 Dimensions: Length (mm) 3298, Width (mm) 1255, Height (mm) 2119, Weight (kg) 1728 Connection Rp 21/2 Serial No.: 2200371822 Year of construction 2021 Condition: Optical 2-3, Techn ...
Process refrigeration machine / chiller air-cooled, Type: TAEevo Tech 402 P3-20 MTA S.p.A. TAEevo Tech 402 P3-20 are air-cooled compact water chillers suitable for outdoor installation (-20°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 500 ltr., built-in P3 Circulation pump and condensation pressure control. Cooling capacity kW 89.4 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 15.2 Available pump pressure (bar) 3.45 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 48 Max. Current (A) 81 Starting Current Circuit (A) 176 Protection class: IP54 Dimensions: Length (mm) 3298, Width (mm) 1255, Height (mm) 2119, Weight (kg) 1728 Connection Rp 21/2 Serial No.: 2200371822 Year of construction 2021 Condition: Optical 2-3, Techn ...
Hauser Maschinen e.K. MTA model TAE EVO M10 water chiller, cooling medium water with a temperature of max. 40°C, refrigerant R407c, refrigerant charge 0.800 kg, refrigerant working pressure max. 28.0 bar, temperature max. 64.5°C, electrics 230V/1Ph/50Hz, max. absorbtion 10.5A, installed power 2.20 kW, protection rating IP32, machine dimensions 550 x 600 x 800 mm (LxWxH), machine net weight approx. 74 kg.
IKG Industriekälte GmbH & Co. KG CYGNUS TECH CY 301 PT1 Compact chiller designed for outdoor installation -10°C - + 46°C suction temperature. Including crank tray heating, buffer tank and built-in P1 circulation pump Cooling capacity kW 69 Cold water temperature outlet/inlet: 7 / 12°C Volume flow m³/h 11.9 Ambient temperature °C 32 Refrigerant R 410A Electrical data: Voltage V 400, Frequency Hz 50, Phase Ph 3 Max. power consumption (kW) 30.5 Max. Current (A) 51 Starting Current Circuit (A) 159 Protection class: IPX4
Process chiller / chiller air-cooled, Type: Aries TECH AST2 115 U MTA S.p.A. The Aries TECH AST2 115 HE are compact chillers suitable for outdoor installation (from -20°C to +48°C) with shell and tube evaporator, four scroll compressors, compressor shut-off valves, crank pan heater, phase monitoring, P3 double pump, tank 598 litres, electric antifreeze heater, condenser filter and control and control cabinet. Cooling capacity (kW): 315 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 53.8 Available. Pump pressure (bar): 2.99 Ambient Temperature (°C): 32 Refrigeration circuit: Refrigerant R 410A Refrigeration Circuits (Quantity): 2 Compressors (quantity): 4 Power levels (%): 0-25-50-75-100 Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW): 158 Max. Current (A): 262 Starting Current Circuit (A): 507 Pr ...
Process chiller / chiller air-cooled, Type: Aries TECH AST2 160 HE MTA S.p.A. The Aries AST2 160 HE are compact chillers designed for outdoor installation (from -20°C to +47°C) are suitable with crank tank heating, phase monitoring, tube bundle evaporator, four scroll compressors, electr. Expansion valves, shut-off valves compressors, storage tank, P3 double pump, electric antifreeze heater, condenser filter, winter control with speed-controlled fans and control and control cabinet. Cooling capacity (kW): 442 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 75.6 Available pump pressure (bar): 2.64 Ambient Temperature (°C): 32 Refrigeration circuit: Refrigerant R 454B Refrigeration Circuits (Quantity): 2 Compressors (quantity): 6 Power levels : 6 Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW): 213 Max ...
Process chiller / chiller air-cooled, Type: Aries TECH AST2 160 HE MTA S.p.A. The Aries AST2 160 HE are compact chillers designed for outdoor installation (from -20°C to +47°C) are suitable with crank tank heating, phase monitoring, tube bundle evaporator, four scroll compressors, electr. Expansion valves, shut-off valves compressors, storage tank, P3 double pump, electric antifreeze heater, condenser filter, winter control with speed-controlled fans and control and control cabinet. Cooling capacity (kW): 442 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 75.6 Available pump pressure (bar): 2.64 Ambient Temperature (°C): 32 Refrigeration circuit: Refrigerant R 454B Refrigeration Circuits (Quantity): 2 Compressors (quantity): 6 Power levels : 6 Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW): 213 Max ...
Inverter heat pumps / chiller air-cooled reversible, Type: Cycnus iHCY 051 PT1+FSH MTA S.p.A. HCYGNUS TECH Inverter iHCY 051 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation up to -15 / -10°C suction temperature. Including crank pan heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 14.6 Heating water temp. Exit/inlet: 45 / 40°C Volume flow m³/h 2.55 Available pump pressure bar: 0.652 Ambient temperature °C +7 Cooling capacity kW 13.1 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 2.22 Available pump pressure bar: 0.771 Ambient temperature °C 32 Refrigerant R 410A Electrical data: Voltage V 400, Frequency Hz 50, Phase Ph 3 Max. power consumption (kW) 7.3 Max. Current (A) 22 Startin ...
Inverter heat pumps / chiller air-cooled reversible, Type: Cycnus iHCY 051 PT1+FSH MTA S.p.A. HCYGNUS TECH Inverter iHCY 051 PT1+FSH are compact heat pumps reversible (heating / cooling) that are suitable for outdoor installation up to -15 / -10°C suction temperature. Including crank pan heater, buffer tank, built-in P1 circulation pump, electric antifreeze heater (evaporator, storage tank and pump) and inverter scroll compressors Heat output kW 14.6 Heating water temp. Exit/inlet: 45 / 40°C Volume flow m³/h 2.55 Available pump pressure bar: 0.652 Ambient temperature °C +7 Cooling capacity kW 13.1 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 2.22 Available pump pressure bar: 0.771 Ambient temperature °C 32 Refrigerant R 410A Electrical data: Voltage V 400, Frequency Hz 50, Phase Ph 3 Max. power consumption (kW) 7.3 Max. Current (A) 22 Startin ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 602 P3 MTA S.p.A. TAEevo Tech 602P3 are compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, electronic expansion valve, buffer tank 500 ltr., built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 116 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 19.8 Available pump pressure (bar) 3.37 Ambient temperature °C 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 60.99 Max. current (A) 102.78 Starting Current Circuit (A) 218.51 Protection class: IP54 Dimensions: Length mm 3294, width mm 1255, height mm 2119, Weight kg 1773 Connection Rp 2 1/2 Serial No.: 2200392538 Year of construction 2022 Condi ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 602 P3 MTA S.p.A. TAEevo Tech 602P3 are compact water chillers suitable for outdoor installation (-5°C to +46°C). Including crank pan heating, phase monitoring, electronic expansion valve, buffer tank 500 ltr., built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 116 Cold water temp. Exit/Entry: 7 / 12°C Volume flow m³/h 19.8 Available pump pressure (bar) 3.37 Ambient temperature °C 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 60.99 Max. current (A) 102.78 Starting Current Circuit (A) 218.51 Protection class: IP54 Dimensions: Length mm 3294, width mm 1255, height mm 2119, Weight kg 1773 Connection Rp 2 1/2 Serial No.: 2200392538 Year of construction 2022 Condi ...
Process chiller / chiller air-cooled, Type: Aries TECH - AST2 140 HE M.T.A. S.p.A. The Aries TECH AST2 140 HE are compact chillers suitable for outdoor installation (from -20°C to +48°C) with four scroll compressors, compressor shut-off valves, crank pan heater, phase monitoring, P2 pump, tank 710 litres, electric antifreeze heater, condenser filter and control and control cabinet and complete housing. Cooling capacity (kW): 371 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 63.5 Available. Pump pressure (bar): 2.33 Ambient Temperature (°C): 32 Refrigeration circuit: Refrigerant R 410A Refrigeration Circuits (Quantity): 2 Compressors (quantity): 4 Power levels (%): 0-25-50-75-100 Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW): 187 Max. Current (A): 300 Starting Current Circuit (A): 633 Protectio ...
Process chiller / chiller air-cooled, Type: Aries TECH - AST2 140 HE M.T.A. S.p.A. The Aries TECH AST2 140 HE are compact chillers suitable for outdoor installation (from -20°C to +48°C) with four scroll compressors, compressor shut-off valves, crank pan heater, phase monitoring, P2 pump, tank 710 litres, electric antifreeze heater, condenser filter and control and control cabinet and complete housing. Cooling capacity (kW): 371 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 63.5 Available. Pump pressure (bar): 2.33 Ambient Temperature (°C): 32 Refrigeration circuit: Refrigerant R 410A Refrigeration Circuits (Quantity): 2 Compressors (quantity): 4 Power levels (%): 0-25-50-75-100 Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW): 187 Max. Current (A): 300 Starting Current Circuit (A): 633 Protectio ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 702 P3 MTA S.p.A. TAEevo Tech 702 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, electronic injection valves, buffer tank 678 ltr. and built-in P3 circulation pump: Cooling capacity kW 136 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 23.1 Available pump pressure (bar) 3.19 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 70.48 Max. current (A) 119.28 Starting Current Circuit (A) 235.01 Protection class: IP54 Dimensions: Length (mm) 3535, Width (mm) 1250, Height (mm) 2151, Weight (kg) 2131 Connection Rp 3 Serial No.: 2200389888 Year of construction 2022 Condition: Optical 2, Technically ok (used) ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 702 P3 MTA S.p.A. TAEevo Tech 702 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, electronic injection valves, buffer tank 678 ltr. and built-in P3 circulation pump: Cooling capacity kW 136 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 23.1 Available pump pressure (bar) 3.19 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 70.48 Max. current (A) 119.28 Starting Current Circuit (A) 235.01 Protection class: IP54 Dimensions: Length (mm) 3535, Width (mm) 1250, Height (mm) 2151, Weight (kg) 2131 Connection Rp 3 Serial No.: 2200389888 Year of construction 2022 Condition: Optical 2, Technically ok (used) ...
Process chiller / chiller air-cooled, Type: - Aries TECH AST 100 SHE – 215 kW Refrigeration Machines, MTA S.p.A. The Aries TECH AST 100 SHE are compact chillers suitable for outdoor installation (from -20°C to +48°C) with shell-and-tube evaporator, four scroll compressors, compressor shut-off valves, crank pan heater, phase monitoring, P2 pump, 400 litre tank, electric antifreeze heater, condenser filter and control and control cabinet. Cooling capacity (kW): 215 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 36.9 Available. Pump pressure (bar): 2.6 Ambient Temperature (°C): 32 Refrigeration circuit: Refrigerant R 410A Refrigeration Circuits (Quantity): 2 Compressors (quantity): 4 Power levels (%): 0-25-50-75-100 Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW): 98 Max. Current (A): 160 Starting ...
Process chiller / chiller air-cooled, Type: - Aries TECH AST 100 SHE – 215 kW Refrigeration Machines, MTA S.p.A. The Aries TECH AST 100 SHE are compact chillers suitable for outdoor installation (from -20°C to +48°C) with shell-and-tube evaporator, four scroll compressors, compressor shut-off valves, crank pan heater, phase monitoring, P2 pump, 400 litre tank, electric antifreeze heater, condenser filter and control and control cabinet. Cooling capacity (kW): 215 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h): 36.9 Available. Pump pressure (bar): 2.6 Ambient Temperature (°C): 32 Refrigeration circuit: Refrigerant R 410A Refrigeration Circuits (Quantity): 2 Compressors (quantity): 4 Power levels (%): 0-25-50-75-100 Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW): 98 Max. Current (A): 160 Starting ...
Process air cooler/chiller/chiller, air-cooled, Type: TAEevo Tech 1002 P3 MTA S.p.A. TAEevo Tech 1002 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 950 ltr., built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 200 [682428 Btu (IT)/h] Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 34.2 Available pump pressure (bar) 3.09 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 99 Max. Current (A) 167 Starting Current Circuit (A) 371 Protection class: IP54 Dimensions: Length (mm) 4655, Width (mm) 1250, Height (mm) 2155 Weight (kg) 2998 Victaulic DN 100 Connector Serial No.: 2200404931 ...
Process air cooler/chiller/chiller, air-cooled, Type: TAEevo Tech 1002 P3 MTA S.p.A. TAEevo Tech 1002 P3 are air-cooled compact water chillers suitable for outdoor installation (from -5°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 950 ltr., built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 200 [682428 Btu (IT)/h] Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 34.2 Available pump pressure (bar) 3.09 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 99 Max. Current (A) 167 Starting Current Circuit (A) 371 Protection class: IP54 Dimensions: Length (mm) 4655, Width (mm) 1250, Height (mm) 2155 Weight (kg) 2998 Victaulic DN 100 Connector Serial No.: 2200404931 ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 802 P3-20 MTA S.p.A. TAEevo Tech 802 P3-20 are air-cooled compact water chillers suitable for outdoor installation (from -20°C to +46°C). Including crank pan heating, phase monitoring, electronic injection valves, buffer tank 678 ltr. and built-in P3 circulation pump. Cooling capacity kW 159 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 27.1 Available pump pressure (bar) 3.13 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 79.48 Max. Current (A) 142.2 Starting Current Circuit (A) 286.2 Protection class: IP54 Dimensions: Length (mm) 3535, Width (mm) 1250, Height (mm) 2151, Weight (kg) 2192 Connection Rp 3 Serial No.: 2200356834 Year of construction 2020 Condition: Optical 2 , Technically ok (u ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 802 P3-20 MTA S.p.A. TAEevo Tech 802 P3-20 are air-cooled compact water chillers suitable for outdoor installation (from -20°C to +46°C). Including crank pan heating, phase monitoring, electronic injection valves, buffer tank 678 ltr. and built-in P3 circulation pump. Cooling capacity kW 159 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 27.1 Available pump pressure (bar) 3.13 Ambient Temperature (°C) 32 Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 79.48 Max. Current (A) 142.2 Starting Current Circuit (A) 286.2 Protection class: IP54 Dimensions: Length (mm) 3535, Width (mm) 1250, Height (mm) 2151, Weight (kg) 2192 Connection Rp 3 Serial No.: 2200356834 Year of construction 2020 Condition: Optical 2 , Technically ok (u ...
Process air cooler/ chiller/ chiller, air-cooled, Type: TAEevo Tech 121 P3-20 MTA S.p.A. TAEevo Tech 121 P3-20 are air-cooled compact water chillers that are suitable for outdoor installation (-20°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 255 ltr., built-in P3 circulation pump and condenser pressure control of the fans. Cooling capacity kW 35 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 5.96 Available pump pressure (bar) 2.67 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 19 Max. current (A) 33 Starting current circuit (A) 165 Protection class: IP54 Dimensions: Length (mm) 1862, Width (mm) 761, Height (mm) 1437, Weight (kg) 652 Connection Rp 1 1/2 Serial No.: 2200382084 Year of construction 2022 Condition: Optical 2, ...
Process air cooler/ chiller/ chiller, air-cooled, Type: TAEevo Tech 121 P3-20 MTA S.p.A. TAEevo Tech 121 P3-20 are air-cooled compact water chillers that are suitable for outdoor installation (-20°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 255 ltr., built-in P3 circulation pump and condenser pressure control of the fans. Cooling capacity kW 35 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 5.96 Available pump pressure (bar) 2.67 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, Frequency 50 Hz, Ph 3 phases, Max. power consumption (kW) 19 Max. current (A) 33 Starting current circuit (A) 165 Protection class: IP54 Dimensions: Length (mm) 1862, Width (mm) 761, Height (mm) 1437, Weight (kg) 652 Connection Rp 1 1/2 Serial No.: 2200382084 Year of construction 2022 Condition: Optical 2, ...
Air cooler, chiller, chiller, air-cooled, Type: TAEevo Tech 101 P3-20 M.T.A. S.p.A. TAEevo Tech 101 P3-20 are air-cooled compact water chillers suitable for outdoor installation (-20°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 255 ltr. , built-in P3 pump and speed control of the fans (winter package). Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 27.5 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 4.68 Available pump pressure (bar) 2.54 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 14 Max. current (A) 25 Starting Current Circuit (A) 123 Protection class: IP54 Dimensions: Length (mm) 1862, Width (mm) 761, Height (mm) 1437, Weight (kg) 637 Connection Rp 11/2 Serial No.: 22004 ...
Air cooler, chiller, chiller, air-cooled, Type: TAEevo Tech 101 P3-20 MTA S.p.A. TAEevo Tech 101 P3-20 are air-cooled compact water chillers suitable for outdoor installation (-20°C to +46°C). Including crank pan heating, phase monitoring, buffer tank 255 ltr. , built-in P3 pump and speed control of the fans (winter package). Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 27.5 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 4.68 Available pump pressure (bar) 2.54 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 14 Max. current (A) 25 Starting Current Circuit (A) 123 Protection class: IP54 Dimensions: Length (mm) 1862, Width (mm) 761, Height (mm) 1437, Weight (kg) 637 Connection Rp 11/2 Serial No.: 22004015 ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 201P3 MTA S.p.A. TAEevo Tech 201 P3 are air-cooled compact water chillers that are suitable for outdoor installation (from -5°C to +46°C). Including crank tray heating, phase monitoring, buffer tank 350 ltr. And built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 44.2 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 7.53 Available pump pressure (bar) 2.67 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 23.69 Max. current (A) 39.83 Starting Current Circuit (A) 134.4 Protection class: IP54 Dimensions: Length (mm) 2250, Width (mm) 866, Height (mm) 2054, Weight (kg) 998 Connection Rp 2 Serial No.: 2200393994 Year of construction 202 ...
Process chiller / chiller air-cooled, Type: TAEevo Tech 201P3 MTA S.p.A. TAEevo Tech 201 P3 are air-cooled compact water chillers that are suitable for outdoor installation (from -5°C to +46°C). Including crank tray heating, phase monitoring, buffer tank 350 ltr. And built-in P3 circulation pump. Cold water outlet temperatures from -10°C to +30°C are adjustable. Cooling capacity kW 44.2 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 7.53 Available pump pressure (bar) 2.67 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 23.69 Max. current (A) 39.83 Starting Current Circuit (A) 134.4 Protection class: IP54 Dimensions: Length (mm) 2250, Width (mm) 866, Height (mm) 2054, Weight (kg) 998 Connection Rp 2 Serial No.: 2200393994 Year of construction 202 ...
Process air cooler/ chiller/ chiller, air-cooled, Type: TAEevo Tech 161 P3 MTA S.p.A. TAEevo Tech 161 are air-cooled compact water chillers that are suitable for outdoor installation. Including crank pan heating, phase monitoring, buffer tank 255 ltr. and built-in P3 Circulating pump. Cooling capacity kW 38.6 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 6.58 Available pump pressure (bar) 2.59 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 21 Max. current (A) 36 Starting Current Circuit (A) 204 Protection class: IP54 Dimensions: Length (mm) 1862, Width (mm) 761, Height (mm) 1437, Weight (kg) 666 Connection Rp 1 1/2 Serial No.: 2200401313 Year of construction 2023 Condition: Optical 2, Technically ok used (Technical changes and prior sale rese ...
Process air cooler/ chiller/ chiller, air-cooled, Type: TAEevo Tech 161 P3 MTA S.p.A. TAEevo Tech 161 are air-cooled compact water chillers that are suitable for outdoor installation. Including crank pan heating, phase monitoring, buffer tank 255 ltr. and built-in P3 Circulating pump. Cooling capacity kW 38.6 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 6.58 Available pump pressure (bar) 2.59 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 21 Max. current (A) 36 Starting Current Circuit (A) 204 Protection class: IP54 Dimensions: Length (mm) 1862, Width (mm) 761, Height (mm) 1437, Weight (kg) 666 Connection Rp 1 1/2 Serial No.: 2200401313 Year of construction 2023 Condition: Optical 2, Technically ok used (Technical changes and prior sale rese ...
process, chiller, chiller, air-cooled, Type: TAEevo Tech 502 P3-20 MTA S.p.A. TAEevo Tech 502P3-20 are air-cooled compact water chillers suitable for outdoor installation (-20°C to +46°C). Cold water temperatures adjustable from -10°C to +30°C. Including crank pan heating, phase monitoring, buffer tank 500 ltr. and built-in P3 circulation pump and speed control of the fans. Cooling capacity kW 105 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 17.9 Available pump pressure (bar) 3.42 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 55.09 Max. current (A) 93.06 Starting Current Circuit (A) 191.65 Protection class: IP54 Dimensions: Length (mm) 3298, Width (mm) 1255, Height (mm) 2119, Weight (kg) 1748 Connection Rp 2 1/2 Serial No.: 2200387388 Year of c ...
chiller, chiller, air-cooled, process refrigeration, Type: TAEevo Tech 502 P3-20 MTA S.p.A. TAEevo Tech 502P3-20 are air-cooled compact water chillers suitable for outdoor installation (-20°C to +46°C). Cold water temperatures adjustable from -10°C to +30°C. Including crank pan heating, phase monitoring, buffer tank 500 ltr. and built-in P3 circulation pump and speed control of the fans. Cooling capacity kW 105 Cold water temp. Exit/Entry (°C): 7 / 12 Volume flow (m³/h) 17.9 Available pump pressure (bar) 3.42 Ambient temperature (°C) 32, Refrigerant R 410A, Electrical data: Voltage V 400, frequency Hz 50, phases Ph 3, Max. power consumption (kW) 55.09 Max. current (A) 93.06 Starting Current Circuit (A) 191.65 Protection class: IP54 Dimensions: Length (mm) 3298, Width (mm) 1255, Height (mm) 2119, Weight (kg) 1748 Connection Rp 2 1/2 Serial No.: 22003873 ...