Turbine counter-pressure turbine KKK CFR5 G6a

energy & engines: power generators, engines, turbines, boilers / turbines

Manufacturer: KKK

Model:CFR5 G6a

Type of machine: Turbine counter-pressure turbine

item-No.: 162733689

Quantity: 1

Date: 11.05.2026

Year of manufacture: 2002

Location: Land-de Germany 55595 Wallhausen

Price:


Your price suggestion:

Seller-item-No.:N0100

Turbine
Turbine mileage: 30,000 hours
Counter-pressure turbine
Manufacturer KKK
Initial commissioning in 2002
Type: CFR5 G6a
Power Max: 2500 kW
Operating power: 2200 kW,
Speed 23000 rpm,
Fresh steam pressure: 65 bar,
Fresh steam pressure temperature: 480 C,
Evaporation pressure: 1-17 bar,
Investments in 2002, Total steam forming station renewed from 63 bar to 2.5 bar in 2002, El. Generator Leroy Somer, el. Power 2 MW, 525 V, 2488 kVA renewed, Complete measuring, control, control technology of the turbine renewed, steam turbine renewed

With

Energy

Installed boiler power
Boiler I Coal Steam generation: 20 t/h, 63 bar, 495 C
Boiler II Coal Steam generation: 13 t/h, 34 bar, 425 C
Boiler III: Combined burner for oil and gas, steam generation: 20 t/h, 17 bar, 285 C
General overhaul of the entire plant from 2002 to 2004, steam generator renewed, automatic charcoal and deserilant plant renewed, water treatment plant renewed, entire control technology renewed, flue gas cleaning plant Lurgie renewed from 1991 to 2001
Investment volume in the entire plant from 2001 to 2004:
€8,800,000.00

Mistakes reserved!

Inquiry

Machinery dealer?

Please remit optionally

Send wanted inquiry?

Copy to you?

Save input data

Turbine
Turbine mileage: 30,000 hours
Counter-pressure turbine
Manufacturer KKK
Initial commissioning in 2002
Type: CFR5 G6a
Power Max: 2500 kW
Operating power: 2200 kW,
Speed 23000 rpm,
Fresh steam pressure: 65 bar,
Fresh steam pressure temperature: 480 C,
Evaporation pressure: 1-17 bar,
Investments in 2002, Total steam forming station renewed from 63 bar to 2.5 bar in 2002, El. Generator Leroy Somer, el. Power 2 MW, 525 V, 2488 kVA renewed, Complete measuring, control, control technology of the turbine renewed, steam turbine renewed

With

Energy

Installed boiler power
Boiler I Coal Steam generation: 20 t/h, 63 bar, 495 C
Boiler II Coal Steam generation: 13 t/h, 34 bar, 425 C
Boiler III: Combined burner for oil and gas, steam generation: 20 t/h, 17 bar, 285 C
General overhaul of the entire plant from 2002 to 2004, steam generator renewed, automatic charcoal and deserilant plant renewed, water treatment plant renewed, entire control technology renewed, flue gas cleaning plant Lurgie renewed from 1991 to 2001
Investment volume in the entire plant from 2001 to 2004:
€8,800,000.00

Mistakes reserved!

seller offer No. resale N0100
can't update statistics 2