Gas generators SIEMENS SGT-300

energy & engines: power generators, engines, turbines, boilers / power generators / Gas generators

Manufacturer: SIEMENS

Model:SGT-300

Type of machine: Gas generators

item-No.: 162755956

Quantity: 1

Date: 13.11.2026

Year of manufacture: 2008

Operating hours: 116131

Location: Land-es Spain

Price:

Machine in stock:No

Seller-item-No.:PTV-1

SIEMENS Gas Turbine CHP and Trigeneration Plant (2008).
Industrial cogeneration and multigeneration plant based on a SIEMENS SGT-300 TEMPEST gas turbine with 7.9 MW ISO output, designed for continuous operation in industrial environments. It operates on natural gas and includes a DLE Dry Low Emission combustion system, 50 Hz frequency, 6.3 kV generator voltage and 1500 rpm generator speed. It is equipped with an Allen-Bradley ControlLogix control system, acoustic enclosure and automatic CO2 fire suppression system.

The plant includes a complete HRSG TRC heat recovery system for the simultaneous production of electricity, steam, thermal oil, as well as the main process equipment and associated services. According to the control panel, the unit records 116131 operating hours and 677 starts. The plant remained operational until it was stopped in November 2025. The HP Rotor was replaced in June 2025, with approximately 8000 remaining operating hours. Batteries for the emergency lubrication pump, gas preheater installed in 2025, filters, spare parts and tools are included.
SIEMENS Gas Turbine CHP and Trigeneration Plant (2008).
Industrial cogeneration and multigeneration plant based on a SIEMENS SGT-300 TEMPEST gas turbine with 7.9 MW ISO output, designed for continuous operation in industrial environments. It operates on natural gas and includes a DLE Dry Low Emission combustion system, 50 Hz frequency, 6.3 kV generator voltage and 1500 rpm generator speed. It is equipped with an Allen-Bradley ControlLogix control system, acoustic enclosure and automatic CO2 fire suppression system.

The plant includes a complete HRSG TRC heat recovery system for the simultaneous production of electricity, steam, thermal oil, as well as the main process equipment and associated services. According to the control panel, the unit records 116131 operating hours and 677 starts. The plant remained operational until it was stopped in November 2025. The HP Rotor was replaced in June 2025, with approximately 8000 remaining operating hours. Batteries for the emergency lubrication pump, gas preheater installed in 2025, filters, spare parts and tools are included.
seller offer No. resale PTV-1
can't update statistics 2